Translational Damper
Linear 1D translational damper
Description
Equations
Variables
Connections
Parameters
Modelica Standard Library
The Translational Damper (or Damper) component models a linear 1-D velocity-dependent translational damper.
f=d⁢vrel=−fa=fb
srel=sb−sa
vrel=s.rel
lossPower=f⁢vrel
Name
Units
Modelica ID
f
N
Forces between flanges
fx
Force applied to flangex,x∈a,b
flange_x.f
srel
m
Relative distance between flanges
s_rel
sx
Absolute position of flangex,x∈a,b
flange_x.s
vrel
ms
Relative velocity between flanges
v_rel
lossPower
W
Loss power leaving component via heatPort
flangea
Left flange of compliant 1-dim. translational component
flange_a
flangeb
Right flange of compliant 1-dim. translational component
flange_b
heatPort
Optional heat port
General Parameters
Default
d
0
N⁢sm
Damping constant
Use Heat Port
false
True (checked) means heat port is enabled
useHeatPort
Advanced Parameters
snominal
1·10−4
Nominal value of srel
s_nominal
State Select
prefer
Prioritize srel and vrel as states
stateSelect
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
1-D Mechanical Overview
Translational Springs and Dampers
Download Help Document