Thermal Ambient IMS
Thermal ambient for induction machine with slip ring
Description
Connections
Parameters
Modelica Standard Library
The Thermal Ambient IMS component models a thermal ambient for an induction machine with slip ring.
Name
Modelica ID
thermalPort
Thermal port
TStatorWinding
Optional real input; temperature of stator windings in K
TRotorWinding
Optional real input; temperature of rotor windings in K
Default
Units
m
3
Number of stator phases
mr
Number of rotor phases
Tr
293.15
K
Temperature of rotor windings
Ts
Temperature of stator windings
Use Temperature Inputs
false
True (checked) means enable temperature inputs
useTemperatureInputs
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Electrical Library
Electrical Machines
Thermal Ambients for Induction Machines