Quasistatic Ideal Core
Ideal transformer with three windings
Description
Equations
Connections
Parameters
Modelica Standard Library
The Quasistatic Ideal Core (or Ideal Core) component models an ideal transformer with three windings. Magnetizing current is not modeled.
i1=ip1
i2=ip2
i3=ip3
ip1+in1=ip2+in2=ip3+in3=0
im=i1+i2n12+i3n13=0
v1=vp1−vn1=n12⁢v2=n13⁢v3
v2=vp2−vn2
v3=vp3−vn3
γp1=γp2=γp3=γn1=γn2=γn3
Name
Modelica ID
plugp1
Positive connection, winding 1
plug_p1
plugn1
Negative connection, winding 1
plug_n1
plugp2
Positive connection, winding 2
plug_p2
plugn2
Negative connection, winding 2
plug_n2
plugp3
Positive connection, winding 3
plug_p3
plugn3
Negative connection, winding 3
plug_n3
Default
Units
m
3
Number of phases
n12
1
Turns ratio 1:2
n13
Turns ratio 1:3
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.