Quasistatic Single Phase Impedance
Single phase linear impedance
Description
Equations
Variables
Connections
Parameters
Modelica Standard Library
The Quasistatic Single Phase Impedance component connects the complex voltage v with the complex current i by v=Z⁢v, where Z is complex.
The model includes a Conditional heat port and temperature dependency of the real part of the impedance.
i=ip=−in
v=vp−vn=Ractual+j⁢Xref⁢i
Ractual=Rref⁢1+αref⁢Thp−Tref
ω=γ.p
γp=γn
Ploss=ℜv⁢i&conjugate0;
Thp={TheatPortUse Heat PortTotherwise
Name
Units
Modelica ID
v
V
Complex RMS voltage
i
A
Complex RMS current
ω
rads
Angular frequency
omega
Ploss
W
Loss power leaving component via the heat port
LossPower
Thp
K
Temperature of HeatPort
T_heatPort
Ractual
Ω
Resistance; temperature dependent
R_actual
pinp
Positive pin
pin_p
pinn
Negative pin
pin_n
Heat Port
Conditional heat port
heatPort
Default
Zref
Complex impedance Zref=Rref+j⁢Xref
Z_ref
Tref
293.15
Reference temperature
T_ref
αref
0
1K
Temperature coefficient of resistance
alpha_ref
Use Heat Port
false
True (checked) means heat port is enabled
useHeatPort
T
Fixed device temperature if useHeatPort = false
Frequency dependent
Consider frequency dependency, if true
frequencyDependent
fref
1
Hz
Relative frequency, if frequency dependency is considered
f_ref
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Electrical Library
Quasistatic Overview
Download Help Document