The Constant Permeance component models a constant magnetic permeance, independent of geometry and permeability of a flux tube.
Φ=Φp=−Φn=Gm⁢Vm
Vm=Vmp−Vmn
Name
Units
Modelica ID
Vm
A
Magnetic potential difference between both ports
V_m
Φ
Wb
Magnetic flux from port_p to port_n
Phi
portp
Positive magnetic port
port_p
portn
Negative magnetic port
port_n
Default
Gm
1
H
Magnetic permeance
G_m