Variable Reluctance - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Variable Reluctance

Maplesoft.Magnetic.QuasiStatic.FluxTubes.Basic.VariableReluctance

 

Description

Equations

Variables

Connections

Modelica Standard Library

Description

The Variable Reluctance component models a signal controlled magnetic reluctance.

Equations

Φ=Φp=Φn

Vm=VmpVmn=RmΦ

Variables

Name

Units

Description

Modelica ID

Vm

A

Magnetic potential difference between both ports

V_m

Φ

Wb

Magnetic flux from port_p to port_n

Phi

Connections

Name

Description

Modelica ID

portp

Positive magnetic port

port_p

portn

Negative magnetic port

port_n

Rm

Real input; magnetic reluctance

R_m

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Magnetic Library

QuasiStatic FluxTubes Basic Components