Fundamental Wave Permeability Sensor
Maplesoft.Magnetic.QuasiStatic.FluxTubes.Sensors.Transient.FundamentalWavePermeabilitySensor
Description
Equations
Connections
Parameters
Modelica Standard Library
The Fundamental Wave Permeability Sensor component determines the effective fundamental wave permeability of a saturated lumped circuit reluctance. For this purpose, the sensor is placed such that the magnetic flux and the magnetic potential difference of the investigated reluctance are sensed. The area of cross section and the effective length of the investigated magnetic path have to be provided as parameters.
μ=ΦVm⁢lA
μr=μμ0
Name
Modelica ID
fluxP
Positive port of flux path
fluxN
Negative port of flux path
potentialP
Positive port of magnetic potential difference path
potentialN
Negative port of magnetic potential difference path
μr
Real output; relative permeability
mur
Default
Units
f
Hz
Fundamental wave frequency
A
m2
Cross section of area penetrated by flux
l
m
Length associated with magnetic potential difference