Air 70 C
Thermal fluid properties for air at 70°C
Description
Parameters
Modelica Standard Library
The Air 70 C (or Air70deg C) component defines the properties of air at 70°C as a thermal-fluid.
Tip: In the model workspace, place this component at the same level as the thermal-fluid components or subsystem to which you want to assign properties. For example, if you place this component at the top level of the model, the thermal-fluid properties will apply to all of the thermal-fluid components and subsystems in your model. If you place this component within a subsystem, the properties defined in the component will apply to the thermal-fluid components in that subsystem only and all nested subsystems.
Name
Default
Units
Modelica ID
ρ
1.015
kgm3
Density
rho
Cp
1010
Jkg⁢K
Specific heat capacity at constant pressure
cp
Cv
723
Specific heat capacity at constant volume
cv
λ
0.0293
Wm⁢K
Thermal conductivity
lambda
ν
20.3·10−6
m2s
Kinematic viscosity
nu