Relative Pressure Sensor - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Rel Pressure Sensor

Pressure difference sensor

 

Description

Equations

Connections

Parameters

Modelica Standard Library

Description

The Relative Pressure Sensor component generates a real signal proportional to the pressure drop from flowPorta to flowPortb. The mass and energy flows into both ports are zero.

Equations

y=papb

Hflowa=0

mflowa=0

Hflowb=0

mflowb=0

Connections

Name

Description

Modelica ID

flowPorta

Thermal-Fluid FlowPort

flowPort_a

flowPortb

Thermal-Fluid FlowPort

flowPort_b

y

Real output; pressure in Pa

y

Parameters

Name

Default

Units

Description

Modelica ID

medium

fluidMedium

 

Thermal-Fluid Media

medium

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Thermal Overview

Thermal Sensors