Moving Boundary Manager, Rotational

Moving Boundary Manager, Rotational calculates normalized contact area ratio between concentric cylindrical / ring sector and shape with 1-D rotational angles.

  

Description

The Moving Boundary Manager, Rotational component is used for calculating normalized contact area ratio between two concentric Cylindrical / Ring Sector and Cylindrical / Ring Shape B components.

This component can take account of 1-D rotational angles connected with 1-D rotational flange.

flange_a is the rotational angle of center of Sector. flange_b is the rotational angle of center of Node[1] in Cylindrical / Ring Shape B.

The order of coefficients of normalized contact area ratio Ac_a and Ac_b output from Real Signal output ports is as follows.

ab1, ... ,abn

The geometry parameters are the following.

Equations

The coefficients of normalized contact area ratio are defined as follows.

 Ac_ai=AiA_a   0  Ac_ai1 Ac_bi=AiA_b    0 Ac_bi1 nc_Ac_a = 1Ac_ak  k=1,..., Nodes_b nc_Ac_bi = 1Ac_bi

Connections

Name

Description

Modelica ID

flange_a

1-D Rotational angle, flange a side, angle of center of Sector

flange_a

flange_b

1-D Rotational angle, flange b side, angle of center of node[1] of Shape

flange_b

Ac_ai

Coefficient of normalized contact area ratio (0 to1) at flange a side

The total number of i is determined by Nodes b

Ac_a[]

Ac_bi

Coefficient of normalized contact area ratio (0 to 1) at flange b side

The total number of i is determined by Nodes b

Ac_b[]

nc_Ac_a

Not contacted area ratio (0 to1) at flange a side

nc_Ac_a

nc_Ac_bi

Not contacted area ratio (0 to1) at flange b side

The total number of i is determined by Nodes b

nc_Ac_b[]

Parameters

Symbol

Default

Units

Description

Modelica ID

θ__a

Pi4

rad

Center angle of Sector (≤π)

theta

Ro__a

1

m

Outer radius of the Sector

Ro_a

Ri__a

0.5

m

Inner radius of the Sector

If Sector is Cylindrical Sector, input 0

Ri_a

Nodes b

4        

 

Number of total nodes of Shape, flange b side

Nodes_b

Ro__b

2

m

Outer radius of the Cylindrical / Ring shape

Ro_b

Ri__b

0

m

Inner radius of the Cylindrical / Ring shape

If Shape is Cylindrical Shape, input 0

Ri_b