Heat Flow Sensor
Heat flow rate sensor
Description
The Heat Flow Sensor component monitors the heat flow rate flowing through it.
This component assumes an ideal situation; no energy is lost between the ports. The output signal is positive if the heat flows from input port_a to port_b.
Equations
Ta=Tb
Qflow.a+Qflow.b=0
Qflow=Qflow.a
Variables
Symbol
Units
Modelica ID
Ta
K
Temperature at port a
Tb
Temperature at port b
Qflow.a
W
Heat flow at port a
Qflow.b
Connections
Name
port_a
Thermal port, a
port_b
Thermal port, b
Q_flow
Real output heat flow rate signal in W
See Also
Heat Transfer Library Overview
Sensors Overview