Controlled Ideal Intermediate Switch - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Home : Support : Online Help : MapleSim : MapleSim Component Library : Electrical : Analog : Switches : Controlled Ideal Intermediate Switch

Controlled Ideal Intermediate Switch

Controlled ideal intermediate switch

 

Description

Connections

Parameters

Modelica Standard Library

Description

The Controlled Ideal Intermediate Switch models a four-terminal, two-pole, electrical switch controlled by an analog signal. When the signal value is greater than the threshold value defined by the level parameter, the switch is in the cross-connection mode and the (isolated) common terminals are connected to the opposing diagonal terminals; otherwise, the switch is in the parallel-connection mode and the common terminals are connected to the opposing parallel terminals.

To prevent singularities during switching, the opened switch has a (very low) conductance Goff and the closed switch has a (very low) resistance Ron.

Connections

Name

Description

Modelica ID

p1

Port 1 positive pin

p1

p2

Port 2 positive pin

p2

n1

Port 1 negative pin

n1

n2

Port 2 negative pin

n2

control

Electrical control

control

Heat Port

Conditional heat port

heatPort

Parameters

Name

Default

Units

Description

Modelica ID

level

0.5

V

Switch threshold level

level

Ron

1·10−5

Ω

Resistance of the closed switch

Ron

Goff

1·10−5

S

Conductance of the opened switch

Goff

Use Heat Port

false

 

True (checked) means heat port is enabled

useHeatPort

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Analog Components

Electrical Library

Switches