Stray Load - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Stray Load

Model of stray load losses dependent on current and speed

 

Description

Equations

Variables

Connections

Parameters

Modelica Standard Library

Description

The Stray Load component models losses dependent of the motor current and shaft speed.

Equations

τ&equals;τrefiIref2{0Pref<0ωωrefpω0ωωωrefpωotherwise

v&equals;vpvn&equals;0

i&equals;ip&equals;in

φ&equals;φflangeφsupport

ω&equals;φ&period;

τ&equals;τsupport&equals;τflange

τref&equals;Prefωref

lossPower&equals;τω

Variables

Name

Units

Description

Modelica ID

v

V

Voltage drop between the two pins

v

i

A

Current flowing from pin p to pin n

i

φ

rad

Angle between shaft and support

phi

τ

Nm

Torque

tau

ω

rads

Relative angular velocity of flange and support

w

lossPower

W

Loss power leaving component via heat port

lossPower

Connections

Name

Description

Modelica ID

p

Positive pin

p

n

Negative pin

n

flange

Shaft end

flange

support

Housing and support

support

heatPort

Conditional heat port

heatPort

Parameters

General Parameters

Name

Default

Units

Description

Modelica ID

use heat port

false

 

true means heatPort is enabled

useHeatPort

Losses Parameters

Name

Default

Units

Description

Modelica ID

Pref

0

W

Reference stray load losses when i&equals;Iref and ω&equals;ωref

PRef

Iref

 

A

Reference RMS current

IRef

ωref

 

rads

Reference angular velocity

wRef

pω

1

1

Exponent of stray load loss torque w.r.t. angular velocity

power_w

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

DC Machine Losses

Electrical Library

Electrical Machines