Current Controller
DQ Current controller
Description
Connections
Parameters
Modelica Standard Library
The DQ Current-Controller (or DQ Current Controller) component is a simple current controller. The desired rms values of d- and q-component of the space phasor current in rotor fixed coordinate system are given by inputs id,rms and iq,rms. Using the given rotor position (input φ), the correct three-phase currents (output y) are calculated. They can be used to feed a current source which in turn feeds an induction machine.
Name
Modelica ID
y
Three-phase real output signals
id,rms
Real input; d-component of desired rms current
id_rms
iq,rms
Real input; q-component of desired rms current
iq_rms
φ
Real input; rotor position in radians
phi
Default
Units
p
Number of pole pairs
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Electrical Library