DQ Current Controller - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Current Controller

DQ Current controller

 

Description

Connections

Parameters

Modelica Standard Library

Description

The DQ Current-Controller (or DQ Current Controller) component is a simple current controller. The desired rms values of d- and q-component of the space phasor current in rotor fixed coordinate system are given by inputs id,rms and iq,rms. Using the given rotor position (input φ), the correct three-phase currents (output y) are calculated. They can be used to feed a current source which in turn feeds an induction machine.

Connections

Name

Description

Modelica ID

y

Three-phase real output signals

y

id,rms

Real input; d-component of desired rms current

id_rms

iq,rms

Real input; q-component of desired rms current

iq_rms

φ

Real input; rotor position in radians

phi

Parameters

Name

Default

Units

Description

Modelica ID

p

 

 

Number of pole pairs

p

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Electrical Library

Electrical Machines

Electrical Machines Utilities