DQ coordinates to three-phase

 

Description

Connections

Parameters

Modelica Standard Library

Description

The From DQ component converts a space-phasor input to a three-phase signal. The two-vector space phase input u is  rotated back to the stator-fixed coordinate system, using the provided mechanical rotor angle φ. The output, y, is the result of the back-transformation to a three-phase value.

Connections

Name

Description

Modelica ID

y

Three-phase real output signals

y

φ

Real input; rotor position in radians

phi

u

Space-phasor input; two vector d and q components

u

Parameters

Name

Default

Units

Description

Modelica ID

p

 

 

Number of pole pairs

p

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.