Ideal Intermediate Switch - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Quasistatic Single Phase Ideal Intermediate Switch

Ideal intermediate switch

 

Description

Equations

Variables

Connections

Parameters

Modelica Standard Library

Description

The Quasistatic Single Phase Ideal Intermediate Switch (or Ideal Intermediate Switch) component models a four-terminal, two-pole, electrical switch that is controlled by a Boolean signal. When the signal is false, the switch is in the cross-connection mode and the (isolated) common terminals are connected to the opposing diagonal terminals. Otherwise, the switch is in the parallel-connection mode and the common terminals are connected to the opposing parallel terminals.

The limiting case is allowed, i.e., the resistance Ron of the closed switch could be exactly zero and the conductance Goff of the open switch could be also exactly zero.

The model includes a Conditional heat port, but no temperature dependency.

Use with care: This switch is only intended to be used for structural changes, not for fast switching sequences, due to the quasistatic formulation.

Equations

in1={1VGoffs1+1As4control1VGoffs4+1As1otherwise

in2={1VGoffs2+1As3control1VGoffs3+1As2otherwise

ip1={1VGoffs1+1As3control1VGoffs3+1As1otherwise

ip2={1VGoffs2+1As4control1VGoffs4+1As2otherwise

γn1=γn2=γp1=γp2

vp1vn1=s11A{1controlRonotherwise

vp1vn2=s31A{Roncontrol1otherwise

vp2vn1=s41A{Roncontrol1otherwise

vp2vn2=s21A{1controlRonotherwise

Ploss=vp1ip1&conjugate0;+vp2ip2&conjugate0;+vn1in1&conjugate0;+vn2in2&conjugate0;

Thp={TheatPortUse Heat PortTotherwise

Variables

Name

Units

Description

Modelica ID

Ploss

W

Loss power leaving component via the heat port

LossPower

Thp

K

Temperature of HeatPort

T_heatPort

Connections

Name

Description

Modelica ID

p1

Port 1 positive pin

p1

p2

Port 2 positive pin

p2

n1

Port 1 negative pin

n1

n2

Port 2 negative pin

n2

control

Boolean input

control

Heat Port

Conditional heat port

heatPort

Parameters

General Parameters

Name

Default

Units

Description

Modelica ID

Ron

1·10−5

Ω

Closed switch resistance

Ron

Goff

1·10−5

S

Opened switch conductance

Goff

Use Heat Port

false

 

True means HeatPort is enabled

useHeatPort

Constant Parameters

Name

Default

Units

Description

Modelica ID

T

293.15

K

Fixed device temperature if Use Heat Port is false

T

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Electrical Library

Quasistatic Overview

Quasistatic Single Phase Ideal Components