Constant Volume
Chamber to model compressible fluid
Description
Equations
Variables
Connections
Parameters
The Constant Volume component models fluid compressibility and contains a mixture of liquid and a small amount of non-dissolved gas, which is used in an approximate model of cavitation.
The fluid bulk modulus, K, and atmospheric pressure, patm come from a Fluid Properties record at the same or higher level in the overall model.
E={Kα=01α+1γ1α⁢K+1k⁢γ⁢β⁢patmotherwise
Vf=V⁢1+pE
β=1+ppatm
γ=β1k
p=pA
q=qA=dVfdt
Name
Units
Modelica ID
p
Pa
Pressure across component
q
m3s
Flow rate through component
portA
Hydraulic port
Default
α
0.005
Relative gas content, VgV
alpha
k
1.4
Heat ratio of gas
V
1
m3
Volume of chamber
See Also
Chambers
Hydraulics Library