Signal Flow Rate - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Signal Flow Rate

Generic flow-rate source using the input signal as the flow rate

 

Description

Equations

Variables

Connections

Description

The Signal Flow Rate component generates a flow rate through its ports proportional to an input signal.

Equations

q=qA=qB=inp

p=pApB

Variables

Name

Units

Description

Modelica ID

p

Pa

Pressure across component

p

q

m3s

Flow rate through component

q

Connections

Name

Description

Modelica ID

portA

Upstream hydraulic port

portA

portB

Downstream hydraulic port

portB

inp

Real input; flow rate in m3s

inp

See Also

Hydraulic Sources

Hydraulics Library