Relief Valve with Pressure-Dependent Flow - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Home : Support : Online Help : MapleSim : MapleSim Component Library : Hydraulics : Valves : Relief Valve with Pressure-Dependent Flow

Relief Valve with Pressure-Dependent Flow

Relief valve with pressure drop computed from table of pressure vs. flow rate

 

Description

Connections

Parameters

Description

The Relief Valve with Pressure-Dependent Flow (or Relief Valve Pressure Dependent Flow) component uses a user-supplied table to define the flow rate for a given pressure drop. It is a general two-port component and not restricted to be a relief valve but is labeled as such and given an appropriate icon for the user's convenience. A similar part is also available as an orifice and a check valve.

The flow rate through the component is computed as a function of the pressure difference between port A and port B from a data table containing values of pressure difference vs the corresponding flow rate.

Pressure vs Flow Rate

For this component, the flow rate must be specified as a function of the pressure difference in the form of a table. The following parameters allows users to specify the necessary data for this calculation.

Data Source: This parameter allows users to specify the nature of the source file for the Pressure vs. flow rate table. The available options are file, attachment, and inline.

file: Use this option to specify a source file (an Excel or a CSV file) located on the hard drive. Use the qdP parameter to browse to and/or select the data file. The data file will not be attached to the MapleSim model.

attachment: Use this option to specify a data file (an Excel or a CSV file) that is attached to the MapleSim model. To be used as an attachment, data files must be attached to the MapleSim model and be categorized under Data Sets. The attached files in a MapleSim model can be viewed in the Attachments pane under the Data Sets section. For more information, see Attaching a File to a Model. If the required file is not already attached to the MapleSim model, use the qdP parameter to attach a new file.

Note:

If the file option is used, subsequent changes to the source file will be incorporated into MapleSim simulations

If the attachment option is used, subsequent changes to the source file will not affect the version attached to the MapleSim model. To ensure updates to the source files are incorporated in the simulation, the file must be reattached.

The Data Generation App can be used to generate table data from mathematical functions using Maple code. For more information about MapleSim apps, see Using MapleSim Apps.

inline: Use this option to directly specify the pressure vs. area relationship in the form of a table. In the qdP parameter, enter an m×2  matrix. The first column must contain values of pressure difference and the second column must contain corresponding values of the area.

Note: To change the dimensions of table, right-click (Control-click for Mac®) the parameter field and select Edit Matrix Dimensions. In the Matrix Dimensions dialog, enter values for the number or rows and columns and then click OK.

Skip rows: This option allows users to specify the number of top rows to be ignored during the calculations. This option can be useful when the Excel file contains header information.

Smooth: The smooth option specifies how the data table is interpolated.

Pressure difference unit: This option specifies the unit of pressure used in the supplied data.

Flow unit: This option specifies the unit of flow rate used in the supplied data.

Optional Volumes

The boolean parameters Use volume A and Use volume B, when true, add optional volumes VA  and VB to ports A and B, respectively. See Port Volumes for details.

If two orifices or valves are connected, enabling a volume at the common port reduces the stiffness of the system and improves the solvability.

Connections

Name

Description

Modelica ID

portA

Upstream hydraulic port

portA

portB

Downstream hydraulic port

portB

Parameters

Flow Rate Vs. Pressure Parameters

Name

Default

Units

Description

Modelica ID

Data source

inline

 

Data source

datasourcemode

qdP

[0,0;100,0;100,0.001;200,0.001]

 

Data set

table

Skip rows

0

 

Number of rows to skip

skipRows

Smooth

0

 

Smoothness of table interpolation

smoothness

Pressure difference unit

kPa

 

Unit of pressure used in the data

pressUnit

flow Unit

Ls

 

Unit flow rate used in the data

flowUnit

Optional Volumes

Name

Default

Units

Description

Modelica ID

useVolumeA

false

 

True (checked) means a hydraulic volume chamber is added to portA

useVolumeA

VA

1·10−6

m3

Volume of chamber A

Va

useVolumeB

false

 

True (checked) means a hydraulic volume chamber is added to portB

useVolumeB

VB

1·10−6

m3

Volume of chamber B

Vb

For more information see Port Volumes.

See Also

Hydraulics Library

Valves