Fundamental Wave Single Phase Winding
Symmetric winding model coupling electrical and magnetic domain
Description
Connections
Parameters
Modelica Standard Library
The Fundamental Wave Single Phase Winding (or Single Phase Winding) component models a single-phase winding. It consists of a single-phase electromagnetic coupling, a resistor in series with the electrical ports, and a symmetrical stray inductor modeled by a reluctance across the magnetic ports. An optional heat port allows thermal flow from the resistor.
Name
Modelica ID
pinp
Positive pin
pin_p
pinn
Negative pin
pin_n
portn
Negative complex magnetic port
port_n
portp
Positive complex magnetic port
port_p
Heat Port Winding
Heat port of winding resistor
heatPortWinding
Default
Units
α
0
1K
Temperature coefficient of winding at 20 degC
alpha20
Lσ
H
Winding stray inductance per phase
Lsigma
neff
1
Effective number of turns per phase
effectiveTurns
Rref
Ω
Winding resistance per phase at TRef
RRef
Toper
293.15
K
Operational temperature of winding
TOperational
Tref
Reference temperature of winding
TRef
θ
rad
Orientation of the resulting fundamental wave field phasor
orientation
Use Heat Port
false
True (checked) means heat port is enabled
useHeatPort
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Magnetic Fundamental Wave
Magnetic Fundamental Wave Basic Machine Components
Magnetic Library
Download Help Document