Fundamental Wave Permeability Sensor - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Fundamental Wave Permeability Sensor

Maplesoft.Magnetic.QuasiStatic.FluxTubes.Sensors.Transient.FundamentalWavePermeabilitySensor

 

Description

Equations

Connections

Parameters

Modelica Standard Library

Description

The Fundamental Wave Permeability Sensor component determines the effective fundamental wave permeability of a saturated lumped circuit reluctance. For this purpose, the sensor is placed such that the magnetic flux and the magnetic potential difference of the investigated reluctance are sensed. The area of cross section and the effective length of the investigated magnetic path have to be provided as parameters.

Equations

μ=ΦVmlA

μr=μμ0

Connections

Name

Description

Modelica ID

fluxP

Positive port of flux path

fluxP

fluxN

Negative port of flux path

fluxN

potentialP

Positive port of magnetic potential difference path

potentialP

potentialN

Negative port of magnetic potential difference path

potentialN

μr

Real output; relative permeability

mur

Parameters

Name

Default

Units

Description

Modelica ID

f

 

Hz

Fundamental wave frequency

f

A

 

m2

Cross section of area penetrated by flux

A

l

 

m

Length associated with magnetic potential difference

l

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Magnetic Library

QuasiStatic FluxTubes Sensors