Description

The Heated Pipe component is a two-port thermal-fluid component that models a pipe with friction loss, head loss, and heat exchange with a heat port.

The Medium parameter specifies the name of a Thermal-Fluid Media record, which must be in the model at the same or higer level.

The Use default medium boolean parameter, when true, sets the name of the Medium parameter to fluidMedium1, which corresponds to the default name of a fluid medium record. To use a different name, uncheck the box and enter the name in the parameter input that appears.

Equations

pdrop&equals;ΔplamVflowVflowlam&plus;{&plus;kVflowVflowlam2Vflowlam<VflowkVflow&plus;Vflowlam2Vflow<Vflowlam0otherwise

h&equals;cpT

Δp&equals;hgρgn&plus;pdrop

Qflow&equals;Qflowport&plus;Qfriction

Qfriction&equals;fLVflowpdrop

TheatPort&equals;Tq

Variables

Name

Units

Description

Modelica ID

Δp

Pa

Pressure drop a->b

dp

pdrop

Pa

 

pressureDrop

Qflow

W

Heat exchange with ambient

Q_flow

Qfriction

W

 

Q_friction

T

K

Outlet temperature of medium

T

ΔT

K

Temperature increase of coolant in flow direction

dT

Ta

K

Temperature at flowPort_a

T_a

Tb

K

Temperature at flowPort_b

T_b

Vflow

m3s

Volume flow from a to b

V_flow

Connections

Name

Description

Modelica ID

flowPorta

Thermal-Fluid FlowPort

flowPort_a

flowPortb

Thermal-Fluid FlowPort

flowPort_b

heatPort

HeatPort

heatPort

Parameters

Name

Default

Units

Description

Modelica ID

fix T0

false

 

True (checked) means T0 is enforced, otherwise it is a guess

T0fixed

fL

0

1

Part of friction losses fed to medium

frictionLoss

hg

0

m

Geodetic height (height difference from flowPort_a to flowPort_b)

h_g

m

1

kg

Mass of medium

m

medium

fluidMedium

 

Thermal-Fluid Media

medium

Δplam

0.1

Pa

Laminar pressure drop

dpLaminar

Δpnom

1

Pa

Nominal pressure drop

dpNominal

T0

293.15

K

Initial temperature of medium

T0

tapT

1

1

Defines temperature of heat port; 0 = inlet temperature, 1 = outlet temperature

tapT

Vflowlam

0.1

m3s

Laminar volume flow

V_flowLaminar

Vflownom

1

m3s

Nominal volume flow

V_flowNominal

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Pipes and Valves

Thermal Overview