Ambient
Ambient with constant properties
Description
Equations
Connections
Parameters
Modelica Standard Library
The Ambient component has a single thermal media flow-port at which the pressure and temperature are either set by parameters or controlled via signals.
The Medium parameter specifies the name of a Thermal-Fluid Media record, which must be in the model at the same or higer level.
The Use default medium boolean parameter, when true, sets the name of the Medium parameter to fluidMedium1, which corresponds to the default name of a fluid medium record. To use a different name, uncheck the box and enter the name in the parameter input that appears.
p={Pinputuse Pambinputpambotherwise
T={Tinputuse TambinputTambotherwise
Name
Modelica ID
flowPort
Thermal-Fluid flow port
Pinput
Real input; ambient pressure in Pa
ambientPressure
Tinput
Real input; ambient temperature temperature in K
ambientTemperature
Default
Units
medium
fluidMedium
Thermal-Fluid Media
pamb
0
Pa
Ambient pressure
constantAmbientPressure
Tamb
293.15
K
Ambient temperature
constantAmbientTemperature
use Pambinput
false
True (checked) means enable pressure input
usePressureInput
use Tambinput
True (checked) means enable temperature input
useTemperatureInput
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Thermal Overview
Thermal Sources
Download Help Document