The Stray Load component models losses dependent of the motor current and shaft speed.
τ=−τref⁢iIref2⁢{0Pref<0ωωrefpω0≤ω−−ωωrefpωotherwise
v=vp−vn=0
i=ip=−in
φ=φflange−φsupport
ω=φ.
τ=τsupport=−τflange
τref=Prefωref
lossPower=−τ⁢ω
Name
Units
Modelica ID
v
V
Voltage drop between the two pins
i
A
Current flowing from pin p to pin n
φ
rad
Angle between shaft and support
phi
τ
N⁢m
Torque
tau
ω
rads
Relative angular velocity of flange and support
w
lossPower
W
Loss power leaving component via heat port
p
Positive pin
n
Negative pin
flange
Shaft end
support
Housing and support
heatPort
Conditional heat port
General Parameters
Default
use heat port
false
true means heatPort is enabled
useHeatPort
Losses Parameters
Pref
0
Reference stray load losses when i=Iref and ω=ωref
PRef
Iref
Reference RMS current
IRef
ωref
Reference angular velocity
wRef
pω
1
Exponent of stray load loss torque w.r.t. angular velocity
power_w