Core
Model of core losses
Description
Equations
Variables
Connections
Parameters
Modelica Standard Library
The Core model uses a constant conductance to model core loss.
The input is a space phasor connector that is normally provided by the output of a space phasor component.
{i=0,Gc=0Pref≤0i=Gc⁢v,Gc=Gc,refotherwise
lossPower=32⁢v⁢i&conjugate0;
Gc,ref=13⁢PrefVref2
Name
Units
Modelica ID
lossPower
W
Loss power leaving component via heatPort
Gc
S
Core loss conductance
i
A
Two-vector space-phasor current representing complex current
v
V
Two-vector space-phasor voltage representing complex voltage
heatPort
Conditional heat port
spacePhasor
Space phasor connector
General Parameters
Default
turns ratio
Effective number of stator turns / effective number of rotor turns
turnsRatio
Use Heat Port
false
True means the heat port is enabled
useHeatPort
Losses Parameters
Pref
0
Reference rotor core losses when v=Vref
PRef
Vref
Reference inner RMS voltage
VRef