Switch YD with Arc - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Switch YD with Arc

Start-Delta switch with arc

 

Description

Connections

Parameters

Modelica Standard Library

Description

The Switch YD with Arc (or Star-Delta Switch with Arc) component uses the Switch YD component with an arc when the switch opens. If the control input is false, plug_sp and plug_sn are star-connected and plug_sp connected to the supply plug. If control is true, plug_sp and plug_sn are delta-connected and they are connected to the supply plug. Note there is a delay between opening star connection and closing delta connection, respectively opening delta connection and closing star connection.

Connections

Name

Description

Modelica ID

plugSupply

To grid

plugSupply

plugsp

To positive stator plug

plug_sp

plugsn

To negative stator plug

plug_sn

control

 

control

Parameters

Name

Default

Units

Description

Modelica ID

m

3

 

Number of phases

m

Ron

1·10−5

Ω

Closed switch resistance

Ron

Goff

1·10−5

S

Opened switch conductance

Goff

Delay time

0

s

Delay time

delayTime

V0

30

V

Initial arc voltage

V0

dVdt

10·103

Vs

Arc voltage slope

dVdt

Vmax

60

V

Max. arc voltage

Vmax

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

Electrical Library

Electrical Machines

Electrical Machines Utilities