Polyphase Triac
Simplified polyphase triac
Description
Connections
Parameters
Modelica Standard Library
The Polyphase Triac component consists of m Single Phase Triac components. The parameter m is the number of output phases.
Thyristor1 has to be fired during the positive halfwave, thyristor2 has to be fired during the negative halfwave.
Name
Modelica ID
fire1
Vectorized boolean input; firing signals for thyristor1
fire2
Vectorized boolean input; firing signals for thyristor2
plugp
Vector of positive connections
plug_p
plugn
Vector of negative connections
plug_n
heatPort
Conditional vector of heat ports
Default
Units
m
3
Number of phases
Ron
1·10−5
Ω
Forward state-on differential resistance
Goff
S
Backward state-off conductance
Vknee
0
V
Forward threshold voltage
Use Heat Port
false
True (checked) means heat port is enabled
useHeatPort
T
20
degC
Fixed temperature, if use heat port is false
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.