Voltage Bridge 2-Pulse
Control of 2 pulse bridge rectifier
Description
Connections
Parameters
Modelica Standard Library
The Voltage Bridge 2 Pulse component has two boolean outputs, firep and firen, that can control the gates of a Thyristor Bridge to rectify a sinusoidal voltage waveform.
In a thyristor bridge, firep controls the thyristors that conduct when the input voltage, acp−acn, is positive, firen controls the thyristors that conduct when the input voltage is negative.
Name
Modelica ID
firingAngle
Conditional real input; firing angle (rad)
acp
Positive voltage sense
ac_p
acn
Negative voltage sense
ac_n
firep
Boolean output
fire_p
firen
fire_n
General Parameters
Default
Units
f
50
Hz
Frequency
Use Constant Firing Angle
true
True (checked) means use constant firing angle instead of signal input
useConstantFiringAngle
Constant Firing Angle
0
rad
Firing angle
constantFiringAngle
Firing Angle Max.
π
Maximum firing angle
firingAngleMax
Filter Parameters
Use Filter
True (checked) means enable use of filter
useFilter
fcut
2⁢f
Cut off frequency of filter
fCut
vstart
V
Start voltage of filter output
vStart
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
AC DC
Electrical Library
Power Converters
Download Help Document