Voltage Bridge 2-Pulse

Control of 2 pulse bridge rectifier

 

Description

Connections

Parameters

Modelica Standard Library

Description

The Voltage Bridge 2 Pulse component has two boolean outputs, firep and firen, that can control the gates of a Thyristor Bridge to rectify a sinusoidal voltage waveform.

In a thyristor bridge, firep controls the thyristors that conduct when the input voltage, acpacn, is positive, firen controls the thyristors that conduct when the input voltage is negative.

Connections

Name

Description

Modelica ID

firingAngle

Conditional real input; firing angle (rad)

firingAngle

acp

Positive voltage sense

ac_p

acn

Negative voltage sense

ac_n

firep

Boolean output

fire_p

firen

Boolean output

fire_n

Parameters

General Parameters

Name

Default

Units

Description

Modelica ID

f

50

Hz

Frequency

f

Use Constant Firing Angle

true

 

True (checked) means use constant firing angle instead of signal input

useConstantFiringAngle

Constant Firing Angle

0

rad

Firing angle

constantFiringAngle

Firing Angle Max.

π

rad

Maximum firing angle

firingAngleMax

Filter Parameters

Name

Default

Units

Description

Modelica ID

Use Filter

true

 

True (checked) means enable use of filter

useFilter

fcut

2f

Hz

Cut off frequency of filter

fCut

vstart

0

V

Start voltage of filter output

vStart

Modelica Standard Library

The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.

See Also

AC DC

Electrical Library