DCV 43 Pump to Tank B - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


DCV 43 Pump To Tank B

4-way 3-position directional control valve

 

Description

Connections

Parameters

Description

The DCV 43 Pump To Tank B component is a four-port, three-position valve. The area between pairs of ports varies as a function of the spool input signal, s, and the parameters Amax, Amin, and band. The following table gives the areas for three values of the spool input.

Spool Input

P-A

P-B

P-T

A-B

A-T

B-T

-1

Amin

Amax

Amin

Amin

Amax

Amin

0

Amax

Amin

Amax

Amin

Amin

Amin

1

Amax

Amin

Amin

Amin

Amin

Amax

Transitions are centered at the midpoint, with the width given by the band parameter, as shown in the following diagram.

Formulation Approaches

One of two approaches can be selected for modeling the flow in the device. When the boolean parameter Use constant Cd is true, a constant coefficient of discharge (Cd) is used, otherwise a variable coefficient of discharge with maximum value (Cdmax) and a critical flow number (Critno) are used.

Optional Volumes

The boolean parameters Use volume A, Use volume B, Use volume P, and Use volume T, when true, add optional volumes VA, VB, VP, and VT to ports A, B, P, and T, respectively. See Port Volumes for details.

If two orifices or valves are connected, enabling a volume at the common port reduces the stiffness of the system and improves the solvability.

Connections

Name

Description

Modelica ID

portA

Hydraulic port A

portA

portP

Hydraulic port P (pump)

portP

portT

Hydraulic port T (tank)

portT

s

Spool input signal

s

Parameters

General

Name

Default

Units

Description

Modelica ID

Amax

1·10−4

m2

Maximum orifice opening area; available when Use scales is true

Amax

Amin

1·10−12

m2

Minimum orifice opening area (leakage)

Amin

band

0.1

 

Transition length in normalized spool displacement units

band

Flip Configuration

false

 

True (checked) flips the order of the valve configuration

Switch

Orifice

Name

Default

Units

Description

Modelica ID

Use constant Cd

true

 

True (checked) means a constant coefficient of discharge is implemented otherwise a variable Cd is used in flow calculations

UseConstantCd

Cd

0.7

 

Flow-discharge coefficient; used when Use constant Cd is true

Cd

ReCr

12

 

Reynolds number at critical flow; used when Use constant Cd is true

ReCr

Coeff

0.7

 

Maximum flow-discharge coefficient; used when Use constant Cd is false

Coeff

Critno

1000

 

Critical flow number; used when Use constant Cd is false

Crit_no

Optional Volumes

Name

Default

Units

Description

Modelica ID

Use volume X

false

 

True (checked) means a hydraulic volume chamber is added to portX

useVolumeX

VX

1·10−6

m3

Volume of chamber attached to portX

Vx

For more information see Port Volumes.

XA,B,P,T

See Also

Directional Control Valves

Hydraulics Library