Magnetic Material with Parameter-based Hysteresis
Description
Parameters
Modelica Standard Library
This magnetic material uses Everett functions to define the B-H hysteresis curve.
This material can be used by the TellinenEverett component in the Magnetic > Shapes > Hysteresis palette; the instance name of material should be copied to the material (mat) parameter of the component, and possibly used in the sigma (σ) parameter, if eddy currents are modeled.
Name
Units
Modelica ID
Hc
Am
Major loop coercivity
Hsat
Hysteresis region is −Hsat to Hsat
K
1
Slope in saturation region is μ0K_
M
Related to saturation value of magnetization
p1
mA
Sharpness of major loop
p2
q
Slope of the straight region in the vicinity of Hc
r
Proportion of the straight region in the vicinity of Hc
σ
Sm
Electrical conductivity of material
sigma
Data
Material
BaseData
7.4
100
0.95
0.12
0.80
0.24
0.55
M270 50A
24.4948
650
50
0.981
0.486
5.49·10−4
0.0273
0.429
1.72·106
M330 50A
42.2283
0.967
0.188
7.81·10−4
0.04
0.503
2.2·106
M400 50A
43.2967
700
0.966
0.299
7.57·10−4
0.0278
0.442
2.22·106
M400 50AP
36.204
600
1.0013
0.318
7.59·10−4
0.0343
0.427
M800 65A
100.0602
1.1461
0.183
4.25·10−4
0.013
0.161
3.27·106
Vacodur 50
133.5844
800
160
1.002
0.796
8.98·10−3
0.0523
1.0835
2.38·106
Vacoflux 17
98.0842
1000
110
0.92
0.0164
1.05·10−3
0.0158
0.728
2.56·106
B-H Curves