Variable Permeance
Maplesoft.Magnetic.QuasiStatic.FluxTubes.Basic.VariablePermeance
Description
Equations
Variables
Connections
Modelica Standard Library
The Variable Permeance component models a signal controlled magnetic permeance.
Φ=Φp=−Φn=Gm⁢Vm
Vm=Vmp−Vmn
Name
Units
Modelica ID
Vm
A
Magnetic potential difference between both ports
V_m
Φ
Wb
Magnetic flux from port_p to port_n
Phi
portp
Positive magnetic port
port_p
portn
Negative magnetic port
port_n
Gm
Real input; magnetic permeance
G_m
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.