Variable Reluctance
Maplesoft.Magnetic.QuasiStatic.FluxTubes.Basic.VariableReluctance
Description
Equations
Variables
Connections
Modelica Standard Library
The Variable Reluctance component models a signal controlled magnetic reluctance.
Φ=Φp=−Φn
Vm=Vmp−Vmn=Rm⁢Φ
Name
Units
Modelica ID
Vm
A
Magnetic potential difference between both ports
V_m
Φ
Wb
Magnetic flux from port_p to port_n
Phi
portp
Positive magnetic port
port_p
portn
Negative magnetic port
port_n
Rm
Real input; magnetic reluctance
R_m
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Magnetic Library
QuasiStatic FluxTubes Basic Components