Orifice ISO 6358 with Pressure-Dependent Flow - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Home : Support : Online Help : MapleSim : MapleSim Component Library : Pneumatics : Restrictions : Orifice ISO 6358 with Pressure-Dependent Flow

Orifice ISO-6358 with Pressure-Dependent Flow

Orifice with pressure-dependent flow rate

Description

Equations

Variables

Connections

Parameters

Description

The Orifice ISO-6358 with Pressure-Dependent Flow component uses a user-supplied table to define the flow rate for a given pressure drop. It is a general two-port component and not restricted to be an orifice but is labeled as such and given an appropriate icon for the user's convenience.

The mass flow rate through the component is computed as a function of the pressure difference between port A and port B from a data table containing values of pressure difference vs. the corresponding flow rate.

If mflowp=mflowp, then the symmetric parameter can be assigned true and only the first quadrant of the mflow vs. p curve needs to be defined in the table.

Pressure vs. Flow Rate

For this component, the mass flow rate must be specified as a function of the pressure difference in the form of a table. The following parameters allows users to specify the necessary data for this calculation.

Data Source: This parameter allows users to specify the nature of the source file for the pressure vs. flow rate table. The available options are file, attachment, and inline.

file: Use this option to specify a source file (an Excel or a CSV file) located on the hard drive. Use the mflowdP parameter to browse to and/or select the data file. The data file will not be attached to the MapleSim model.

attachment: Use this option to specify a data file (an Excel or a CSV file) that is attached to the MapleSim model. To be used as an attachment, data files must be attached to the MapleSim model and be categorized under Data Sets. The attached files in a MapleSim model can be viewed in the Attachments pane under the Data Sets section. For more information, see Attaching a File to a Model. If the required file is not already attached to the MapleSim model, use the mflowdP parameter to attach a new file.

Note:

If the file option is used, subsequent changes to the source file will be incorporated into MapleSim simulations

If the attachment option is used, subsequent changes to the source file will not affect the version attached to the MapleSim model. To ensure updates to the source files are incorporated in the simulation, the file must be reattached.

The Data Generation App can be used to generate table data from mathematical functions using Maple code. For more information about MapleSim apps, see Using MapleSim Apps.

inline: Use this option to directly specify the pressure vs. area relationship in the form of a table. In the mflowdP parameter, enter an m×2 matrix. The first column must contain values of pressure difference and the second column must contain corresponding values of the area.

Note: To change the dimensions of table, right-click (Control-click for Mac®) the parameter field and select Edit Matrix Dimensions. In the Matrix Dimensions dialog, enter values for the number or rows and columns and then click OK.

Skip rows: This option allows users to specify the number of top rows to be ignored during the calculations. This option can be useful when the Excel file contains header information.

Smoothness: The smoothness option specifies how the data table is interpolated.

Pressure difference unit: This option specifies the unit of pressure used in the supplied data.

Mass Flow unit: This option specifies the unit of flow rate used in the supplied data.

Equations

p=pApB  hflow__X  = inStreamportXhflow

mflow=mflowA=mflowB={signpsymmetric1otherwiseInterpolate1DmflowdP,{psymmetricpotherwisepressUnit,2,smoothness,skipRows

Variables

Name

Units

Description

Modelica ID

p

Pa

Pressure drop from A to B

p

mflow

kgs

Mass flow rate from port A to port B

mflow

hflowX

Jkg

Specific Enthalpy into port X

hflowX

Connections

Name

Description

Modelica ID

portA

Upstream Pneumatic port

portA

portB

Downstream Pneumatic port

portB

Parameters

Valve Characteristics

Name

Default

Description

Modelica ID

symmetric

true

True (checked) means the data for positive pressure difference is used for both directions

symmetric

 

Mass Flow Rate Vs. Pressure

Name

Default

Description

Modelica ID

Data source

inline

Data source

datasourcemode

mflowdP

0,0;10,0;50,0.001; 100,0.001

Data set

table

Skip rows

0

Number of rows to skip

skipRows

Smoothness

linear

Smoothness of table interpolation

smoothness

Pressure difference unit

kPa

Unit of pressure used in the data

pressUnit

m__flow unit

kgs

Unit of mass flow rate used in the data

mflow_flowUnit

See Also

Pneumatics Library

Restrictions