Mass Flow Rate - MapleSim Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Mass Flow Rate Source

Generic mass flow-rate source using the input signal or constant value as the flow rate

Description

Equations 

Variables

Connections

Parameters

Description

The Mass Flow Rate Source component generates a flow rate proportional to the specified value or an input signal.

Equations

mflow=mflowA==inp

p=pApBhflow__X  = inStreamportXhflow  

Variables

Name

Units

Description

Modelica ID

p

Pa

Pressure at portA

p

mflow

kgs

Mass flow rate at portA

mflow

hflowX

Jkg

Specific Enthalpy into port X

hflowX

Connections

Name

Description

Modelica ID

portA

Upstream Pneumatic port

portA

inp

Real input; mass flow rate in kgs

inp

See Also

Pneumatic Sources

Pneumatics Library

Parameters

Mass flow

 

Name

Default

Units

Description

Modelica ID

Mdot

0.001

kgs

Mass flow rate at port A

mdot

 

Fluid medium Parameters

The Gas parameters used in the equations, are properties defined in the Gas Model component used in the model.

Name

Default

Units

Description

Modelica ID

Use default medium

true

When true the default gas properties defined for Air will be used.

useDefaultMedium

medium

when Use default medium is false this option gets turned on. The user can specify the name of the Gas model dragged into the canvas.

medium