Gas Orifice Flow Meter Calculator - Maple Help
For the best experience, we recommend viewing online help using Google Chrome or Microsoft Edge.

Online Help

All Products    Maple    MapleSim


Gas Orifice Flow Meter Calculator

This application calculates the flow rate through a large-diameter orifice using the approach outlined in ISO 5167 2:2003.

Orifice meters use the pressure loss across a constriction (that is, the orifice plate) in a pipe to determine the flow rate.  

The formulas are valid for the following parameters:

• 

Pipe diameters between 50mm and 1000 mm

• 

Pressure ratios greater than 0.75

Reference: http://en.wikipedia.org/wiki/Orifice_plate

 

Pipe Diameter D1 (m)

Molecular Weight

Orifice Diameter D2 (m)

Compressibility Factor

Upstream Pressure P1 (Pa)

Specific Heat Ratio

Downstream Pressure P2 (Pa)

Fluid Viscosity (Pa s)

Upstream Temperature (K)

Tap Type

 

 m3 s-1

 

 

 

Legal Notice: © Maplesoft, a division of Waterloo Maple Inc. 2015. Maplesoft and Maple are trademarks of Waterloo Maple Inc. Neither Maplesoft nor the authors are responsible for any errors contained within and are not liable for any damages resulting from the use of this material.  This application is intended for non-commercial, non-profit use only. Contact the authors for permission if you wish to use this application in for-profit activities.