The Rotational EMF (or EMF) component transforms electrical energy into rotational mechanical energy. It is used as a basic building block for an electrical motor. The mechanical connector, flange, can be connected to rotational mechanical components.
i=ip=−in
v=vp−vn=k⁢w
w=φ.
φ=φflange−φinternal
τflange=−k⁢i
Name
Units
Modelica ID
v
V
Voltage drop between the two pins
vx
Voltage at pin x, x∈n,p
x.v
i
A
Current flowing from positive to negative pin
ix
Current into pin x, x∈n,p
x.i
φ
rad
Angle of shaft flange with respect to support
phi
w
rads
Angular velocity of flange relative to support
p
Positive pin
n
Negative pin
flange
Rotational flange
support
Support/housing of emf shaft
Default
k
1
N⁢mA
Transformation coefficient
Use Support Flange
false
True (checked) means the rotational port is enabled
useSupport
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.