Ideal Intermediate Switch
Ideal intermediate switch
Description
Connections
Parameters
Modelica Standard Library
The Ideal Intermediate Switch component models a four-terminal, two-pole, electrical switch that is controlled by a Boolean signal. When the signal is false, the switch is in the cross-connection mode and the (isolated) common terminals are connected to the opposing diagonal terminals. Otherwise, the switch is in the parallel-connection mode and the common terminals are connected to the opposing parallel terminals.
To prevent singularities during switching, the opened switch has a (very low) conductance Goff and the closed switch has a (very low) resistance Ron.
Name
Modelica ID
p1
Port 1 positive pin
p2
Port 2 positive pin
n1
Port 1 negative pin
n2
Port 2 negative pin
control
Boolean input
Heat Port
Conditional heat port
heatPort
Default
Units
Ron
1·10−5
Ω
Resistance of the closed switch
Goff
S
Conductance of the opened switch
Use Heat Port
false
True (checked) means heat port is enabled
useHeatPort
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.