Ideal Transformer
Ideal transformer core with or without magnetization
Description
Equations
Variables
Connections
Parameters
Modelica Standard Library
The Ideal Transformers (or Ideal Transformer) component models an ideal, two-winding transformer.
If the boolean parameter Consider Magnetization is true, a magnetizing inductance is added in parallel with port 1.
{ψm1=Lm1⁢im1,v1=ψ.m1Consider Magnetizationψm1=0,im1=0otherwise
i1=ip1=−in1
i2=ip2=−in2
im1=i1+i2n
v1=vp1−vn1=n⁢v2
v2=vp2−vn1
Name
Units
Modelica ID
v1
V
Voltage drop over the left port
v2
Voltage drop over the right port
i1
A
Current flowing from pos. to neg. pin of the left port
i2
Current flowing from pos. to neg. pin of the right port
p1
Positive pin of the left port
n1
Negative pin of the left port
p2
Positive pin of the right port
n2
Negative pin of the right port
Default
n
1
Turns ratio
Consider Magnetization
false
True (checked) means include magnetizing inductance
considerMagnetization
Lm1
H
Magnetization inductance w.r.t. primary side
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.