Logic To Real
Logic to Real converter
Description
Equations
Connections
Parameters
Modelica Standard Library
The Logic to Real component converts a digital input to a Real output.
The parameter n sets the width of the input and output.
yk=valuexk
Name
Modelica ID
x
Digital input
y
Real output
Default
Units
n
1
Signal width
valueU
0.5
Value for digital uninitialized
value_U
valueX
Value for digital forcing Unknown
value_X
value0
0
Value for digital forcing 0
value_0
value1
Value for digital forcing 1
value_1
valueZ
Value for digital high impedance
value_Z
valueW
Value for digital weak unknown
value_W
valueL
Value for digital weak 0
value_L
valueH
Value for digital weak 1
value_H
valuem
Value for digital don't care
value_m