Damper Cage
Description
Equations
Variables
Connections
Parameters
Modelica Standard Library
The Damper Cage component models an asymmetrical damper cage in two axes.
Rrdactual=Rrd⁢1+α⁢Thp−Tref
Rrqactual=Rrq⁢1+α⁢Thp−Tref
vSPr1=Rrdactual⁢iSPr1+Lrσd⁢iSPr1.
vSPr2=Rrqactual⁢iSPr2+Lrσq⁢iSPr2.
23⁢LossPower=Rrdactual⁢iSPr12+Rrqactual⁢iSPr22
Thp={TheatPortUse Heat PortTotherwise
Name
Units
Modelica ID
LossPower
W
Loss power leaving component via HeatPort
Thp
K
Temperature of HeatPort
T_heatPort
Rrdactual
Ω
Actual resistance resistance in d-axis
Rrd_actual
Rrqactual
Actual resistance resistance in q-axis
Rrq_actual
i
Currents out from damper
SPr
Rotor space phasor
spacePhasor_r
lossPower
Damper losses
Heat Port
Conditional heat port
heatPort
Default
Lrσd
H
Stray inductance in d-axis per phase translated to stator
Lrsigmad
Lrσq
Stray inductance in q-axis per phase translated to stator
Lrsigmaq
Rrd
Resistance in d-axis per phase translated to stator at Tref
Rrq
Warm resistance in q-axis per phase translated to stator
α
0
1K
Temperature coefficient of both resistances in d- and q-axis at Tref
alpha
Use Heat Port
false
True (checked) means heat port is enabled
useHeatPort
T
Tref
Fixed device temperature if Use Heat Port is false
293.15
Reference temperature of both resistances in d- and q-axis
T_ref