Squirrel Cage
Description
Equations
Variables
Connections
Parameters
Modelica Standard Library
The Squirrel Cage component models a squirrel cage/symmetrical damper cage in two axes.
Rractual=Rr⁢1+α⁢Thp−Tref
vSPr=Rractual⁢iSPr+Lrσ⁢i.SPr
23⁢LossPower=Rractual⁢iSPr12+iSPr22
Thp={TheatPortUse Heat PortTotherwise
Name
Units
Modelica ID
LossPower
W
Loss power leaving component via HeatPort
Thp
K
Temperature of HeatPort
T_heatPort
Rractual
Ω
Actual resistance
Rr_actual
Heat Port
Conditional heat port
heatPort
SPr
Space phasor
spacePhasor_r
Default
Lrσ
H
Rotor stray inductance per phase translated to stator
Lrsigma
Rr
Warm rotor resistance per phase translated to stator
Use Heat Port
false
True (checked) means heat port is enabled
useHeatPort
α
0
1K
Temperature coefficient of resistance at T_ref
alpha
T
Tref
Fixed device temperature if Use Heat Port is false
293.15
Reference temperature
T_ref
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Electrical Library
Electrical Machine Components
Electrical Machines
Download Help Document