Thermal Ambient IMS

Thermal ambient for induction machine with slip ring

 

Description

Connections

Parameters

Modelica Standard Library

Description

The Thermal Ambient IMS component models a thermal ambient for an induction machine with slip ring.

Connections

Name

Description

Modelica ID

thermalPort

Thermal port

thermalPort

TStatorWinding

Optional real input; temperature of stator windings in K

TStatorWinding

TRotorWinding

Optional real input; temperature of rotor windings in K

TRotorWinding

Parameters

Name

Default

Units

Description

Modelica ID

m

3

 

Number of stator phases

m

mr

m

 

Number of rotor phases

mr

Tr

293.15

K

Temperature of rotor windings

Tr

Ts

293.15

K

Temperature of stator windings

Ts

Use Temperature Inputs

false

 

True (checked) means enable temperature inputs

useTemperatureInputs