Switched Rheostat

Rheostat which is shorted after a given time.

 

Description

Connections

Parameters

Modelica Standard Library

Description

The Switched Rheostat component models a switched rheostat; it is used for starting an asynchronous induction motor with a slip-ring rotor. The external rotor resistance Rstart is shorted at time tstart.

Connections

Name

Description

Modelica ID

plugp

To positive rotor plug

plug_p

plugn

To negative rotor plug

plug_n

Parameters

Name

Default

Units

Description

Modelica ID

m

3

 

Number of phases

m

Rstart

 

Ω

Starting resistance

RStart

tstart

 

s

Time the starting resistance is shorted

tStart