Polyphase Ideal Commuting Switch
Polyphase ideal commuting switch
Description
Connections
Parameters
Modelica Standard Library
The Polyphase Ideal Commuting Switch (or Ideal Commuting Switch) component contain m single-phase ideal commuting switch models, each connected between corresponding phases of plugp, plugn1, and plugn2, with the control from the corresponding signal in the control vector input.
A vector of optional thermal ports, one for each switch, is enabled if Use Heat Port is true.
Name
Modelica ID
plugp
Positive m-phase plug
plug_p
plugn2
Negative m-phase plug (normally opened)
plug_n2
plugn1
Negative m-phase plug (normally closed)
plug_n1
control
Boolean vector input
Heat Port
Optional heat ports
heatPort
Default
Units
m
3
Number of phases
Ron
* 1·10−5
Ω
Closed switch resistance
Goff
* FLOATE(1,-5)
S
Opened switch conductance
Use Heat Port
false
True (checked) means heat ports are enabled
useHeatPort
* Starred values are vector parameters; the default is fill⁡x,m, which creates a vector with m entries of x.
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
Electrical Library
Polyphase Overview
Polyphase Switches
Download Help Document