Voltage Bridge 2m-Pulse
Control of 2m pulse bridge rectifier
Connections
Parameters
Modelica Standard Library
Name
Description
Modelica ID
firingAngle
Firing angle (rad)
ac
firep
fire_p
firen
fire_n
General Parameters
Default
Units
m
3
Number of phases
f
50
Hz
Frequency
Use Constant Firing Angle
true
True (checked) means use constant firing angle instead of signal input
useConstantFiringAngle
Constant Firing Angle
0
rad
Firing angle
constantFiringAngle
Firing Angle Max.
π
Maximum firing angle
firingAngleMax
Filter Parameters
Use Filter
True (checked) means enable use of filter
useFilter
fcut
2⁢f
Cut off frequency of filter
fCut
vstart
zeros⁡m
V
Start voltage of filter output
vStart
The component described in this topic is from the Modelica Standard Library. To view the original documentation, which includes author and copyright information, click here.
See Also
AC DC
Electrical Library
Power Converters
Download Help Document