Tellinen Permanent Magnet
Permanent magnet based on the Tellinen hysteresis model
Description
Equations
Variables
Connections
Parameters
Modelica Standard Library
The Tellinen Permanent Magnet component is a flux tube element of fixed length and cross-sectional area that models the hard magnetic hysteresis of permanent magnets. The model is similar to Tellinen Hard but has an initial magnetization preset of -100% and an adapted icon for better readability of the diagram.
Φ=Φp=−Φn=B⁢A
Vm=Vmp−Vmn
H=Vmℓ=Hstat+Heddy
Heddy={σ⁢d212⁢dBdtInclude eddy currents0otherwise
H0=12⁢log⁡1+μ0⁢HcBr1−μ0⁢HcBr+M⁢Hc
hystF=Js⁢tanh⁡Hstat⁢M+H0Hunit+μ0⁢Hstat+12⁢eps
hystR=Js⁢tanh⁡Hstat⁢M−H0Hunit+μ0⁢Hstat−12⁢eps
{dHyst=0,k=1100initialdHyst=ddt−Hstat⁢μ0+hystR,k=max⁡1100,hystF−BΔhyst0<dHstatdtdHyst=ddt−Hstat⁢μ0+hystF,k=max⁡1100,B−hystRΔhystotherwise
LossPower=LossPowerstat+LossPowereddy
LossPowereddy=Heddy⁢dBdt⁢V
LossPowerstat=Hstat⁢dBdt⁢V
Δhyst=hystF−hystR
dBdt=k⁢dHyst+μ0⁢dHstatdt
dMagReldt=0
Thp={TheatPortUse Heat PortTotherwise
Name
Units
Modelica ID
B
T
Magnetic flux density
dHyst
Ts
Slope of the limiting hysteresis branch
H
Am
Magnetic field strength
Heddy
Dynamic (eddy currents) portion of the magnetic field strength
Hstat
Static (ferromagnetic) portion of the magnetic field strength
LossPower
W
Loss power leaving component via HeatPort
LossPowereddy
Eddy current losses (dynamic hysteresis losses)
LossPowerEddy
LossPowerstat
Ferromagnetic (static) hysteresis losses
LossPowerStat
MagRel
1
Relative magnetization at initialization (-1..1)
Φ
Wb
Magnetic flux from port_p to port_n
Phi
TheatPort
K
Temperature of HeatPort
T_heatPort
Vm
A
Magnetic potential difference between both ports
V_m
portp
Positive magnetic port
port_p
portn
Negative magnetic port
port_n
heatPort
Conditional heat port
Hystersis
Default
Br
1.2
Remanence
Hc
5·105
Coercitivity
μ0 multiplier
M
10⁢HunitHc
Slope of tanh function
Fixed Geometry
ℓ
0.1
m
Length in direction of flux
l
1·10−4
m2
Area of cross section
Losses And Heat Parameters
Use Heat Port
false
True (checked) enables heat port
useHeatPort
Include Eddy Currents
True (checked) enables eddy current losses
includeEddyCurrents
σ
1·107
Sm
Conductivity of core material
sigma
d
5·10−4
Thickness of lamination